Pass-Through Dishwasher
PT-M
For an individual consultation or if you have any questions, please contact us
- Phone +44 (0)1908 359-000
E-Ma3lu5hil (infow/tpj@wk1interhaly8terw72.co.ukgu3b)
PT-M pass-through dishwasher.
Brilliant, fast and efficient cleaning.
With a rack size of 500 x 500 mm, the PT-M pass-through dishwasher offers enough space for most types of dishes. Depending on the application, the compact machine model is available as a dishwasher, bistro dishwaher, glasswasher or cutlery washer.
The elliptical wash fields, VarioPower washing pressure adjustment and the innovative full-flow filtration guarantee perfect cleaning results.
The active Energy Management shortens the heating and wash cycles. The standard EnergyLight heat recovery system saves valuable energy with every wash cycle, thereby reducing your operating costs.
Thanks to additional equipment options, the machine can be optimally adapted to your individual requirements.
The innovative design of the PT Series guarantees a top performance for perfect cleaning results - brilliant, fast and efficient.
Technical data: PT-M
PT Series according to model in [mm]: | |
Technical Information | PT-M |
---|---|
Width | 635 |
Height with feet | 1.995 |
Depth | 750 |
Slight input height | 440 |
Tank contents [l] | 35,0 |
Water protection class | IP X5 |
Dishes | |||||
Technical Information | Unit | Standard | EnergyPlus | HighTemp | ClimatePlus |
---|---|---|---|---|---|
Theoretic capacity | [Racks/h] | 44 / 32 / 22 | 44 / 32 / 22 | 25 / 20 / 15 | 44 / 32 / 22 |
Short programme | [Racks/h] | 72 | 72 | --- | 72 |
Rinse water volume* | [l] | 2,4 | 2,4 | 3,8 | 2,4 |
Rinse temperature | [°C] | 85 | 85 | 85 | 85 |
Tank temperature | [°C] | 62 | 62 | 66 | 62 |
Water inlet temperature | [°C] | 60 | 20 | 60 | 20 |
Total connection value 6,4 (10,8) kW / validation | [kW] | 400V / 3N~: 7,9 (9,1) kW / 16 A 400V / 3N~: 10,2 (13,2) kW / 25 A 400V / 3N~: --- (14,7) kW / 32 A 230V / 1N~: 6,9 (---) kW / 32 A |
400V / 3N~: 7,9 (9,1) kW / 16 A 400V / 3N~: 10,2 (13,2) kW / 25 A 400V / 3N~: --- (14,7) kW / 32 A 230V / 1N~: 6,9 (---) kW / 32 A |
400V / 3N~: 7,9 (9,1) kW / 16 A 400V / 3N~: 10,2 (13,2) kW / 25 A 400V / 3N~: --- (14,7) kW / 32 A 230V / 1N~: 6,9 (---) kW / 32 A |
380V / 3N~: 7,1 kW / 16 A 400V / 3N~: 7,9 kW / 16 A 400V / 3N~: 10,2 kW / 25 A / 32 A 415V / 3N~: 6,9 kW / 15 A 415V / 3N~: 8,4 kW / 16 A / 20 A 415V / 3N~: 10,9 kW / 25 A 230V / 3~: 7,8 kW / 25 A 230V / 3~: 10,1 kW / 32 A |
Glasses | ||||
Technical Information | Unit | Standard | EnergyPlus | ClimatePlus |
---|---|---|---|---|
Theoretic capacity | [Racks/h] | 22 / 32 / 48 | 22 / 32 / 48 | 22 / 32 / 48 |
Short programme | [Racks/h] | 77 | 77 | 77 |
Rinse water volume* | [l] | 2,4 | 2,4 | 2,4 |
Rinse temperature | [°C] | 65 | 65 | 65 |
Tank temperature | [°C] | 62 | 62 | 62 |
Water inlet temperature | [°C] | 60 | 20 | 20 |
Total connection value 6,4 (10,8) kW / validation | [kW] | 400V / 3N~: 7,9 (9,1) kW / 16 A 400V / 3N~: 10,2 (13,2) kW / 25 A 400V / 3N~: --- (14,7) kW / 32 A 230V / 1N~: 6,9 (---) kW / 32 A |
400V / 3N~: 7,9 (9,1) kW / 16 A 400V / 3N~: 10,2 (13,2) kW / 25 A 400V / 3N~: --- (14,7) kW / 32 A 230V / 1N~: 6,9 (---) kW / 32 A |
380V / 3N~: 7,1 kW / 16 A 400V / 3N~: 7,9 kW / 16 A 400V / 3N~: 10,2 kW / 25 A / 32 A 415V / 3N~: 6,9 kW / 15 A 415V / 3N~: 8,4 kW / 16 A / 20 A 415V / 3N~: 10,9 kW / 25 A 230V / 3~: 7,8 kW / 25 A 230V / 3~: 10,1 kW / 32 A |
Bistro | ||||
Technical Information | Unit | Standard | EnergyPlus | ClimatePlus |
---|---|---|---|---|
Theoretic capacity | [Racks/h] | 28 / 32 / 40 | 28 / 32 / 40 | 28 / 32 / 40 |
Short programme | [Racks/h] | 72 | 72 | 72 |
Rinse water volume* | [l] | 2,4 | 2,4 | 2,4 |
Rinse temperature | [°C] | 85 | 85 | 85 |
Tank temperature | [°C] | 62 | 62 | 62 |
Water inlet temperature | [°C] | 60 | 20 | 20 |
Total connection value 6,4 (10,8) kW / validation | [kW] | 400V / 3N~: 7,9 (9,1) kW / 16 A 400V / 3N~: 10,2 (13,2) kW / 25 A 400V / 3N~: --- (14,7) kW / 32 A 230V / 1N~: 6,9 (---) kW / 32 A |
400V / 3N~: 7,9 (9,1) kW / 16 A 400V / 3N~: 10,2 (13,2) kW / 25 A 400V / 3N~: --- (14,7) kW / 32 A 230V / 1N~: 6,9 (---) kW / 32 A |
380V / 3N~: 7,1 kW / 16 A 400V / 3N~: 7,9 kW / 16 A 400V / 3N~: 10,2 kW / 25 A / 32 A 415V / 3N~: 6,9 kW / 15 A 415V / 3N~: 8,4 kW / 16 A / 20 A 415V / 3N~: 10,9 kW / 25 A 230V / 3~: 7,8 kW / 25 A 230V / 3~: 10,1 kW / 32 A |
Cutlery | |||
Technical Information | Unit | Standard | EnergyPlus |
---|---|---|---|
Theoretic capacity | [Racks/h] | 11 | 11 |
Short programme | [Racks/h] | 21 | 21 |
Rinse water volume* | [l] | 4,0 | 4,0 |
Rinse temperature | [°C] | 86 | 86 |
Tank temperature | [°C] | 69 | 69 |
Water inlet temperature | [°C] | 60 | 20 |
Total connection value 6,4 (10,8) kW / validation | [kW] | 400V / 3N~: 7,9 (9,1) kW / 16 A 400V / 3N~: 10,2 (13,2) kW / 25 A 400V / 3N~: --- (14,7) kW / 32 A 230V / 1N~: 6,9 (---) kW / 32 A |
400V / 3N~: 7,9 (9,1) kW / 16 A 400V / 3N~: 10,2 (13,2) kW / 25 A 400V / 3N~: --- (14,7) kW / 32 A 230V / 1N~: 6,9 (---) kW / 32 A |
The technical data provided here are based on an operation under ideal conditions. Depending on the local circumstances, individual values may vary and must be recalibrated on startup..
* Non-binding information. The actual need for rinse water can vary depending on the on-site conditions.