Utensil washers of the UF Series and the GS 630. Maximum wash power for your perfect results.

The powerful utensil washers of the UF Series and GS 630 are the perfect choice for your kitchen equipment.

Depending on your available space and the items to be washed, you can choose between the smallest utensil washer of the world, the GS 630 or the new UF-M, UF-L or UF-XL with various innovative features.

All of our machines deliver hygienically perfect cleaning results, are ergonomic and easy to handle and save valuable energy.

Complementary products

Water treatment | Racks | Chemicals
Product consultant
Winterhalter product consultant

Technical data: Utensil Washers

GS 630
Technical Information Unit Standard
Theoretic capacity [Racks/h] 38 / 29 / 12
Width [mm] 870
Depth closed/open [mm] 600 / 1070
Height with feet [mm] 820 (835) 820 - 835
Working height [mm] 325 ± 20
Passage height [mm] 410
Rack dimensions [mm] 650 x 508
Rinse water volume* [l] 4.4
Tank temperature [°C] 60
Boiler temperature [°C] 85 / 65 (Temperature switching optional)
Total connection value 10 - 40 °C / 40 -55 °C / 55 - 60 °C) [kW] 7.1 / 7.1 / 7.1
Dishes - Equipment to GN 1/1, trays up to 600 x 400 mm
UF-M
Technical Information Unit Standard Energy HighTemp
Theoretic capacity [Racks/h] 40 / 24 / 12 40 / 24 / 12 40 / 24 / 12
Theoretic capacity short programme [Racks/h] 64 / 42 / 23 64 / 42 / 23 ---
Rinse water volume* [l] 4,7 4,7 5,5
Tank temperature [°C] 60 60 66
Rinse temperature [°C] 85 85 85
Max inlet water temperature [°C] 60 20 60
Tank heating standard / performance [kW] 5 / 10 5 / 10 --- / 10
Boiler heating standard / performance [kW] 10,2 / 16,4 10,2 / 16,4 --- / 16,4
Total connection value 380V / 3N~ 50/60 Hz:
8,7 / --- kW / 16 A
400V / 3N~ 50/60 Hz:
9,4 / --- kW / 16 A
400V / 3N~ 50/60 Hz:
10,0 / --- kW / 20 A
400V / 3N~ 50/60 Hz:
16,3 / 16,4 kW / 25 A
400V / 3N~ 50/60 Hz:
17,5 / 18,8 kW / 32 A
400V / 3N~ 50/60 Hz:
--- / 24,1kW / 16 A
415V / 3N~ 50/60 Hz:
10,0 / --- kW / 16 A
415V / 3N~ 50/60 Hz:
10,8 / --- kW / 20 A
415V / 3N~ 50/60 Hz:
17,4 / 17,7 kW / 25 A
415V / 3N~ 50/60 Hz:
18,7 / 20,3 kW / 32 A
415V / 3N~ 50/60 Hz:
--- / 25,5 kW / 40 A
380V / 3N~ 50/60 Hz:
8,7 / --- kW / 16 A
400V / 3N~ 50/60 Hz:
9,4 / --- kW / 16 A
400V / 3N~ 50/60 Hz:
10,0 / --- kW / 20 A
400V / 3N~ 50/60 Hz:
16,3 / 16,4 kW / 25 A
400V / 3N~ 50/60 Hz:
17,5 / 18,8 kW / 32 A
400V / 3N~ 50/60 Hz:
--- / 24,1kW / 16 A
415V / 3N~ 50/60 Hz:
10,0 / --- kW / 16 A
415V / 3N~ 50/60 Hz:
10,8 / --- kW / 20 A
415V / 3N~ 50/60 Hz:
17,4 / 17,7 kW / 25 A
415V / 3N~ 50/60 Hz:
18,7 / 20,3 kW / 32 A
415V / 3N~ 50/60 Hz:
--- / 25,5 kW / 40 A
400V / 3N~ 50/60 Hz:
--- / 16,4 kW / 25 A
400V / 3N~ 50/60 Hz:
--- / 18,8 kW / 32 A
415V / 3N~ 50/60 Hz:
--- / 17,7 kW / 25 A
415V / 3N~ 50/60 Hz:
--- / 20,3 kW / 32 A
415V / 3N~ 50/60 Hz:
--- / 25,5 kW / 40 A
UF-L
Technical Information Unit Standard Energy HighTemp
Theoretic capacity [Racks/h] 40 / 24 / 12 40 / 24 / 12 40 / 24 / 12
Theoretic capacity short programme [Racks/h] 64 / 42 / 23 64 / 42 / 23 64 / 42 / 23
Rinse water volume* [l] 4,7 4,7 5,5
Tank temperature [°C] 60 60 66
Rinse temperature [°C] 85 85 85
Max inlet water temperature [°C] 60 20 60
Tank heating standard / performance [kW] 5 / 10 5 / 10 --- / 10
Boiler heating standard / performance [kW] 10,2 / 16,4 10,2 / 16,4 --- / 16,4
Total connection value 380V / 3N~ 50/60 Hz:
8,7 / --- kW / 16 A
400V / 3N~ 50/60 Hz:
9,4 / --- kW / 16 A
400V / 3N~ 50/60 Hz:
10,0 / --- kW / 20 A
400V / 3N~ 50/60 Hz:
16,3 / 16,4 kW / 25 A
400V / 3N~ 50/60 Hz:
17,5 / 18,8 kW / 32 A
400V / 3N~ 50/60 Hz:
--- / 24,1kW / 16 A
415V / 3N~ 50/60 Hz:
10,0 / --- kW / 16 A
415V / 3N~ 50/60 Hz:
10,8 / --- kW / 20 A
415V / 3N~ 50/60 Hz:
17,4 / 17,7 kW / 25 A
415V / 3N~ 50/60 Hz:
18,7 / 20,3 kW / 32 A
415V / 3N~ 50/60 Hz:
--- / 25,5 kW / 40 A
380V / 3N~ 50/60 Hz:
8,7 / --- kW / 16 A
400V / 3N~ 50/60 Hz:
9,4 / --- kW / 16 A
400V / 3N~ 50/60 Hz:
10,0 / --- kW / 20 A
400V / 3N~ 50/60 Hz:
16,3 / 16,4 kW / 25 A
400V / 3N~ 50/60 Hz:
17,5 / 18,8 kW / 32 A
400V / 3N~ 50/60 Hz:
--- / 24,1kW / 16 A
415V / 3N~ 50/60 Hz:
10,0 / --- kW / 16 A
415V / 3N~ 50/60 Hz:
10,8 / --- kW / 20 A
415V / 3N~ 50/60 Hz:
17,4 / 17,7 kW / 25 A
415V / 3N~ 50/60 Hz:
18,7 / 20,3 kW / 32 A
415V / 3N~ 50/60 Hz:
--- / 25,5 kW / 40 A
400V / 3N~ 50/60 Hz:
--- / 16,4 kW / 25 A
400V / 3N~ 50/60 Hz:
--- / 18,8 kW / 32 A
415V / 3N~ 50/60 Hz:
--- / 17,7 kW / 25 A
415V / 3N~ 50/60 Hz:
--- / 20,3 kW / 32 A
415V / 3N~ 50/60 Hz:
--- / 25,5 kW / 40 A
UF-XL
Technical Information Unit Standard Energy HighTemp
Theoretic capacity [Racks/h] 40 / 24 / 12 40 / 24 / 12 40 / 24 / 12
Theoretic capacity short programme [Racks/h] 64 / 42 / 23 64 / 42 / 23 ---
Rinse water volume* [l] 7 7 9
Tank temperature [°C] 60 60 66
Rinse temperature [°C] 85 85 85
Max inlet water temperature [°C] 60 20 60
Tank heating standard / performance [kW] 5 / 10 5 / 10 --- / 10
Boiler heating standard / performance [kW] 10,2 / 16,4 10,2 / 16,4 --- / 16,4
Total connection value 380V / 3N~ 50/60 Hz:
8,4 / --- kW / 16 A
400V / 3N~ 50/60 Hz:
8,8 / --- kW / 16 A
400V / 3N~ 50/60 Hz:
10,0 / --- kW / 20 A
400V / 3N~ 50/60 Hz:
16,2 / 16,4 kW / 25 A
400V / 3N~ 50/60 Hz:
17,4 / 18,8 kW / 32 A
400V / 3N~ 50/60 Hz:
--- / 26,2 kW / 16 A
415V / 3N~ 50/60 Hz:
9,5 / --- kW / 16 A
415V / 3N~ 50/60 Hz:
10,8 / --- kW / 20 A
415V / 3N~ 50/60 Hz:
17,1 / 17,7 kW / 25 A
415V / 3N~ 50/60 Hz:
18,4 / 20,3 kW / 32 A
415V / 3N~ 50/60 Hz:
21,1 / 26,8 kW / 40 A
380V / 3N~ 50/60 Hz:
8,4 / --- kW / 16 A
400V / 3N~ 50/60 Hz:
8,8 / --- kW / 16 A
400V / 3N~ 50/60 Hz:
10,0 / --- kW / 20 A
400V / 3N~ 50/60 Hz:
16,2 / 16,4 kW / 25 A
400V / 3N~ 50/60 Hz:
17,4 / 18,8 kW / 32 A
400V / 3N~ 50/60 Hz:
--- / 26,2 kW / 16 A
415V / 3N~ 50/60 Hz:
9,5 / --- kW / 16 A
415V / 3N~ 50/60 Hz:
10,8 / --- kW / 20 A
415V / 3N~ 50/60 Hz:
17,1 / 17,7 kW / 25 A
415V / 3N~ 50/60 Hz:
18,4 / 20,3 kW / 32 A
415V / 3N~ 50/60 Hz:
21,1 / 26,8 kW / 40 A
400V / 3N~ 50/60 Hz:
--- / 16,4 kW / 25 A
400V / 3N~ 50/60 Hz:
--- / 18,8 kW / 32 A
415V / 3N~ 50/60 Hz:
--- / 17,7 kW / 25 A
415V / 3N~ 50/60 Hz:
--- / 20,3 kW / 32 A
415V / 3N~ 50/60 Hz:
--- / 26,8 kW / 40 A

The technical data provided here are based on an operation under ideal conditions. Depending on the local circumstances, individual values may vary and must be recalibrated on startup..

* Non-binding information. The actual need for rinse water can vary depending on the on-site conditions.